PENGUJIAN REFRIGERAN ALTERNATIF RAMAH LINGKUNGAN PADA MESIN PENDINGIN JENIS KOMPRESI UAP

Authors

  • Tri Widagdo Politeknik Negeri Sriwijaya

Keywords:

Alternative Refrigerant, Refrigeratiom optimation

Abstract

The Vapor Compretion Refrigeration Machine is very commonly used, either for home or industuial scale. The pefomance of machine is depend on the quality of the fluid (refigerant) that operated. The refrigerant that usally used is R-12 that have very good thrmoynamic properties. In fact this refrigerant came from the CFC’s (Chlorofluoride Carbonate), is the substance which have potency to detruct the inviromenthal system. From that writer tend to do research that concern with same alternative refrigrerant. They are R-134, Butana and Petrozon. The perfomance that result from machine than compared with the perfomance of refrigeration machine that operatet with R-12 refrigerant. Research activity begun with instaling refigerant machine complatet with experimanthal divice and control system. Using the R-12 refrigerant, the maximum COP is 2.21. The COP of refrigeration machine that operated with alteranative refrigerant are: 1. For Butana the maximum COP is 2.1 at low cooling load and evaporator pressure 2.6 bar 2. For R-134a the maximum COP is 2.4 at high cooling load and evaporator pressure 1.2 bar 3. For Petrozon the maximum COP is 2.2 at high cooling load and evaporator pressure 2.6 bar

Downloads

Download data is not yet available.

References

1. Charles, N., 1988., ‘Trancience of Refrigeration Proccess’., ASHRAE Journal of Refrigeration 243, Paris
2. Damitri N.,Soekardi C., Suwono A., dan Tandian N.P.,1999,
‘Perfomance Comparison of CFC-12, HVR-12 and HCR+LFS as Refrigerant’, Seminar on ODS Phase-out: Solution for the Refrigeration Sector, Kuta.
3. Holman,J.P.,alih bahasa Suprapto,
1990, ‘Perrpindahan
Panas’.,edisi 4, Pradnya
Paramita, Jakarta
4. Reynolds and Perkins, alih bahasa
Harahap.P., dan Silaban P.,
1992, ‘Termodinamika Teknik”,
Penerbit Airlangga, Jakarta
5. Stocker,W., 1995, ‘Refrigeration and Air Conditioning’, 4th edition, Pantice-Hall, Washington DC
6. Suwono A., Pasek A.D. dan Tandian N.P., 1996, ‘Mencari Refrigeran Ramah Lingkungan’, Republika, 5 Juuni 1996
7. Tandian N.P., Suwono A, Sylvia C.A. dan Psaek A.D.,1997,
‘Application of Prophane-
Buthane Mixture As Refrigeran in a Milk Cooling Unit’., Prosseding of Fluid and Thermal Energy Concersion.
8. Walker & Marry, 1988, ‘Hydrocarbon, Mixing & Handling’., 3rd ,Pradt
& Whitney book Co, Singapore

Downloads

Published

2010-10-01

How to Cite

Widagdo, T. (2010). PENGUJIAN REFRIGERAN ALTERNATIF RAMAH LINGKUNGAN PADA MESIN PENDINGIN JENIS KOMPRESI UAP. AUSTENIT, 2(02). Retrieved from https://jurnal.polsri.ac.id/index.php/austenit/article/view/113

Similar Articles

You may also start an advanced similarity search for this article.